| Product model | ALRS-120 | ALRS-150 | |
| Meet a criterion | TUVEN60950,EN61558-1/-2-16,UL60950-1,GB4943 | ||
| Output | DC voltage (V) |
5V、12V、24V、36V、48V |
5V、12V、24V、36V、48V |
| Rated current (A) | 20A、10A、5A、3.3A、2.5A | 22A、12.5A、6.5A、4.3A、3.3A | |
| Rated power (W) | 100W、120W、120W、118.8W、120W | 110W、150W、156W、154.8W、158.4W | |
| Ripple and noise | 100mVp-p、150mVp-p、200mVp-p、200mVp-p、200mVp-p | ||
|
Ripple swept noise |
±10% | ||
| Voltage accuracy | 5V ±2.0% 12~48V ±1.0% | ||
| Linear adjustment rate | 5V ±0.5% 12~48V ±0.5% | ||
| Load regulation rate | 5V ±1.0% 12~48V ±0.5% | ||
| Start up time | 500ms、30ms/230VAC 500ms、30ms/115VAC | ||
| Keep time | 55ms/230VAC 10ms/115VAC | 40ms/230VAC 35ms/115VAC | |
| Import | Voltage range/frequency | 85-264VAC 120-373VDC/47Hz~63Hz | 85-132VAC 170-264VDC/47Hz~63Hz |
| Efficiency (typical) | 86% 88% 90% 90.5% 91% | 85% 87.5% 89% 89% 90% | |
| Working current | 2A/115VAC 1.3A/230VAC | 3A/115VAC 1.7A/230VAC | |
|
Shock current |
50A/230VAC |
60A/230VAC | |
| Leakage current | <1mA 240VAC | <1mA 240VAC | |
| Protect | Overload protection | ≥110%-130% | |
| Overvoltage protection |
≥115%-145% |
||
| Environment | Working temperature and humidity | -30℃~+70℃; 20%~90RH | |
| Storage temperature and humidity | -40℃~+85℃; 10%~95RH | ||
| Safety standard | Pressure resistance |
Input-output:4KVAC Input-output(enclosure):2KVAC/1.25KVAC |
|
| Insulation impedance | Input-output(enclosure):500VDC/100MΩ | ||
|
Else |
Size | 129*97*30mm(L*W*H) | 159*97*30mm(L*W*H) |
| Net weight/Gross weight | 340g/365g | 480g/513g | |