FILTER*Select the corresponding category and view the product

SMC-N Reversing Contactor
Select
SMC AC Contactor
Miniature Circuit Breaker (MCB)
SMSE
AOV2
QJX2
SAU Aux.Contacts Blocks
Single Function
AGK / AGKM
Mini Molded Case Circuit Breaker (Mini MCCB)
CJX2 AC Contactor 3-Pole
Time Relay
SMS
Phase Failure Protection Relay
CJX2 AC Contactor 4-Pole
Digital Display
AOV3
QJX3
SAC Capacitor Unit
Mini Earth Leakage Circuit Breaker (Mini ELCB)
DC Miniature Circuit Breaker (DC MCB)
SMC Large Capacity Contactor
AFKV-NH/NHF/HF (Digital Display)
SMC-C Capacitor Contactor
CJX2-N Reversing Contactor
Molded Case Circuit Breaker (MCCB)
ADGK (Digital Display)
Voltage Protection Relay
Double Delay
SAR Mechanical Interlock Unit
Residual Current Circuit Breaker
CJX2-Z DC Contactor
SMC-Z DC Contactor
Surge Protective Device (SPD)
Earth Leakage Circuit Breaker (ELCB)
Multifunction
SAZ Separate Mounting Base
AFKD/ADFK (Digital Display)
Over Current Protection Relay
CJ19 Capacitor Contactor
SMC-N Reversing Contactor
F8/F4 Aux. Contacts Blocks
DC Molded Case Circuit Breaker (DC MCCB)
DC Surge Protective Device (DC SPD)
PV Fuse
Phase Protection Relay
Miniature Switch Disconnecter (MSD)
JR28 Thermal Overload Relay
CJ19 Switchover Capacitor Unit
PV Connector
MR Contactor Relay
Under Voltage Protection Relay
Modular Contactors
Contactor Relay
LA2/LA3 Air Timer Delay
PV Combiner Box
Special Electronic Contactor
SMR Thermal Overload Relay
Consumer Unit
LA9 Mechanical Interlock Unit
D.O.L Motor Starter
Motor Circuit Breaker
Level Control Relays
SAZ1 Separate Mounting Base
SMS D.O.L Motor Starter
CJX2N-D AC Contactor
AORD Over Current Protection Relay
AOCR-SS
AOV2 Shunt Release/ Upper Auxiliary
AOR2 Thermal Overload Relay
AOCR-AR
AOV2 Waterproof Mounting Box
AOCR-SSD
Star-Delta Starters
AUCR
AOCR-SE2
Moulded Case Circuit Breaker
AOUE Type 1+2
Earth Leakage Circuit Breaker
AOX1-□M/HLN
AOUE Type 2
AOCT-M Manual Operation
Moulded Case DC Circuit Breaker
AOCT Electric Operation
Circuit Breaker for Specific Purpose
AOUE Type 2+3
AOX1-□M/L
AOX1-□M/HL
Circuit Breaker
PM-12
Three-Phase Distribution Box
AOX1-□M/HLB
AOX1-□M
Circuit Breaker Accessories
Ammeter
MSD is given priority to switch the consumer units
MSD is given priority to switch and RCD division unit load consumer
MSD is given priority to switch and RCD division 2 load consumer units
RCD is given priority to switch the consumer units
2 RCD is given priority to switch the consumer units
2 MSD is given priority to switch the consumer units
MSD is given priority to switch and SPD division unit load consumer
AOU Acoustic and Visualin Dicator
ASR
PR-30/DRP-6D
QCX2
Voltmeter
Frequency Meter
Multimeter
AOS
SMC-P2
SMC-D2/D3
Contactor Aux.Contacts Blocks
SAU Aux.Contacts Blocks
Contactor Capacitor Unit
SAC Capacitor Unit
Contactor Mechanical Interlock Unit
SAR Mechanical Interlock Unit
Thermal Relay Separate Mounting Base
SAZ Separate Mounting Base
Contactor Air Timer Delay
Motor Circuit Breaker Waterproof Mounting Box
Motor Circuit Breaker Shunt Release/ Upper Auxiliary
AOLE
AOLR
AVSR
SMC Contactor Accessories
DIN Rail Electric Meter
Pointer Type Electric Meter
Mutual Inductor
AORD
ATRM (Digital Display)
Overvoltage and Undervoltage Protection Relay
Products
SMC Contactor and Protection Relay
Distribution Electrical Appliances
Time and Protection Relay
Electrical Measuring Instruments
Terminal Electrical Appliances
Motor Control and Protection

SMC-9/12/18/22N Reversing Contactor

SMC-N Reversing Contactor

Characteristics

● 3 pairs of main contacts.
● Mechanical interlock unit.
● Design of anti-electric shock cover.
● Installation of guide rail or screw.
● The accessory can be mounted on the top or at side.
● Be connected with the thermal overioad relay directly.

Technical parameters:

Type

Rated Current

AC3(IEC60947)

Ac1 Ith

Aux.Contacts

200-240V

380-440V

500-550V

660-690V

SMC-9N

9A

2.5kW 11A

4kW 9A

4kW 7A

4kW 5A

25A

Optional

SMC-12N

12A

3.5kW 13A

5.5kW 12A

7.5kW 12A

7.5kW 9A

25A

Optional

SMC-18N

18A

4.5kW 18A

7.5kW 18A

7.5kW 13A

7.5kW 9A

40A

Optional

SMC-22N

22A

5.5kW 22A

11kW 22A

15kW 22A

15kW 18A

40A

Optional

SMC-32N

32A

7.5kW 32A

15kW 32A

18.5kW 28A

18.5kW 20A

50A

Optional

SMC-40N

40A

11kW 40A

18.5kW 40A

22kW 32A

22kW 23A

60A

Optional

SMC-50N

50A

15KW 55A

22kW 50A

30kW 43A

30kW 28A

80A

Optional

SMC-65N

65A

18.5KW 65A

30kW 65A

33kW 60A

33kW 35A

100A

Optional

SMC-75N

75A

22kW 75A

37kW 75A

37kW 64A

37kW 42A

110A

Optional

SMC-85N

85A

25kW 85A

45kW 85A

45kW 75A

45kW 45A

135A

Optional

SMC-100N
100A
30kW 100A
55kW 100A
55kW 85A
55kW 65A
150A
Optional

 

Coil Voltage AC50/60Hz:

24、48、110、220/230、380/400、420/440V


Mechanical Interlock Unit:




Combination Chart:

 

Dimensions(mm):

If you have any enquiry about quotation or cooperation,please feel free to email us ator use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.