FILTER*Select the corresponding category and view the product

AOCT-M Manual Operation
Select
SMC AC Contactor
Miniature Circuit Breaker (MCB)
SMSE
AOV2
QJX2
SAU Aux.Contacts Blocks
Single Function
AGK / AGKM
Mini Molded Case Circuit Breaker (Mini MCCB)
CJX2 AC Contactor 3-Pole
Time Relay
SMS
Phase Failure Protection Relay
CJX2 AC Contactor 4-Pole
Digital Display
AOV3
QJX3
SAC Capacitor Unit
Mini Earth Leakage Circuit Breaker (Mini ELCB)
DC Miniature Circuit Breaker (DC MCB)
SMC Large Capacity Contactor
AFKV-NH/NHF/HF (Digital Display)
SMC-C Capacitor Contactor
CJX2-N Reversing Contactor
Molded Case Circuit Breaker (MCCB)
ADGK (Digital Display)
Voltage Protection Relay
Double Delay
SAR Mechanical Interlock Unit
Residual Current Circuit Breaker
CJX2-Z DC Contactor
SMC-Z DC Contactor
Surge Protective Device (SPD)
Earth Leakage Circuit Breaker (ELCB)
Multifunction
SAZ Separate Mounting Base
AFKD/ADFK (Digital Display)
Over Current Protection Relay
CJ19 Capacitor Contactor
SMC-N Reversing Contactor
F8/F4 Aux. Contacts Blocks
DC Molded Case Circuit Breaker (DC MCCB)
DC Surge Protective Device (DC SPD)
PV Fuse
Phase Protection Relay
Miniature Switch Disconnecter (MSD)
JR28 Thermal Overload Relay
CJ19 Switchover Capacitor Unit
PV Connector
MR Contactor Relay
Under Voltage Protection Relay
Modular Contactors
Contactor Relay
LA2/LA3 Air Timer Delay
PV Combiner Box
Special Electronic Contactor
SMR Thermal Overload Relay
Consumer Unit
LA9 Mechanical Interlock Unit
D.O.L Motor Starter
Motor Circuit Breaker
Level Control Relays
SAZ1 Separate Mounting Base
SMS D.O.L Motor Starter
CJX2N-D AC Contactor
AORD Over Current Protection Relay
AOCR-SS
AOV2 Shunt Release/ Upper Auxiliary
AOR2 Thermal Overload Relay
AOCR-AR
AOV2 Waterproof Mounting Box
AOCR-SSD
Star-Delta Starters
AUCR
AOCR-SE2
Moulded Case Circuit Breaker
AOUE Type 1+2
Earth Leakage Circuit Breaker
AOX1-□M/HLN
AOUE Type 2
AOCT-M Manual Operation
Moulded Case DC Circuit Breaker
AOCT Electric Operation
Circuit Breaker for Specific Purpose
AOUE Type 2+3
AOX1-□M/L
AOX1-□M/HL
Circuit Breaker
PM-12
Three-Phase Distribution Box
AOX1-□M/HLB
AOX1-□M
Circuit Breaker Accessories
Ammeter
MSD is given priority to switch the consumer units
MSD is given priority to switch and RCD division unit load consumer
MSD is given priority to switch and RCD division 2 load consumer units
RCD is given priority to switch the consumer units
2 RCD is given priority to switch the consumer units
2 MSD is given priority to switch the consumer units
MSD is given priority to switch and SPD division unit load consumer
AOU Acoustic and Visualin Dicator
ASR
PR-30/DRP-6D
QCX2
Voltmeter
Frequency Meter
Multimeter
AOS
SMC-P2
SMC-D2/D3
Contactor Aux.Contacts Blocks
SAU Aux.Contacts Blocks
Contactor Capacitor Unit
SAC Capacitor Unit
Contactor Mechanical Interlock Unit
SAR Mechanical Interlock Unit
Thermal Relay Separate Mounting Base
SAZ Separate Mounting Base
Contactor Air Timer Delay
Motor Circuit Breaker Waterproof Mounting Box
Motor Circuit Breaker Shunt Release/ Upper Auxiliary
AOLE
AOLR
AVSR
SMC Contactor Accessories
DIN Rail Electric Meter
Pointer Type Electric Meter
Mutual Inductor
AORD
ATRM (Digital Display)
Overvoltage and Undervoltage Protection Relay
Products
SMC Contactor and Protection Relay
Distribution Electrical Appliances
Time and Protection Relay
Electrical Measuring Instruments
Terminal Electrical Appliances
Motor Control and Protection

AOCT-63M 3NO Modular Contactor (Manual operation)

AOCT-M Manual Operation

Characteristics

AOCT series Household AC Contactor (also called modular AC Contactor), is mainly used in power systems with current 50Hz/60Hz, rated working voltage up to 400V, and rated working current up to 100A. Under the AC-1, AC-7a (No-inductive or low-inductive load, resistance furnace, household appliances or low-inductive load for similar purposes) usage category, it can be used as remote switch and control circuit, and also can be used to control household motor load. Household AC contactors are not used to break short-circuit current, so appropriate short-circuit protection appliances (such as Micro Circuit Breaker) should be selected when in use. Compliance with IEC61095, GB17885 standards.
AOCT Household AC Contactor has expandable auxiliary control, protection and indication functions. Mainly used in homes, hotels, apartments, office buildings, public buildings, shopping centers, stadiums and other places.

Model Specification:



Main Technical Parameter:  

Type Specification

Electirc Operation

AOCT-16

AOCT-20

AOCT-25

AOCT-40

AOCT-63

AOCT-100

Manual Operation

AOCT-16M
AOCT-20M
AOCT-25M
AOCT-40M
AOCT-63M
AOCT-100M

Rated current

AC-7a

16

20

25

40

63

100

AC-7b

6

7

8.5

15

20

30

Conventional Thermal Current   lth(A) 

25

25

25

63

63

100

Rated Insulated Voltage   Ui(V)

500

Rated Operational Voltage   Ue(V)

250V(1P/2P) 400V(3P/4P)

Number of Main Contacts  

1P

1NO、1NC

2P

1NO+1NC、2NO、2NC

3P

3NO、3NC

4P

2NO+2NC、3NO+1NC、4NO、4NC

Control Power  

AC-7a

230V

3.5

4.5

5.5

9

14

22

400V

6.5

8

10

16

25

38

AC-7b

230V

1.4

1.6

2

3.5

4.5

6.5

400V

2.4

2.8

3.4

6

8

11

Electrical Life (Times)  

1 hundred thousand

Mechanical Life (Times)  

1 million

Maximum number of switch operations per hour  

30

Maximum number of switch operations per day  

100

Quota Control Power Supply Voltage   Us (V)

AC 24/50Hz AC230/50Hz

Frequency

50Hz/60Hz

Pollution Level  

2

Rated Withstand Voltage(Uimp)

2.5kV(4kV--12/24/48VAV)

(IEC60529)

Protection Level

Contactor Only  

IP20

Installed in the distribution box  

IP40

Operational Temperature

-5℃~+60℃

Storage Temperature  

-40℃~+70℃

(IEC60068.1)

Heat Resistance

The relative humidity is 95% when the temperature is 55℃

ELSV(Ultra-low safety voltage)12/24/48VAC


Technical Parameter


Dimensions(mm):

AOCT-40M/63M

If you have any enquiry about quotation or cooperation,please feel free to email us ator use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.